Truss fixings. Straps should go under rafters and over ceiling joists.

Strap Nail. A galvanised nail has a slightly rough surface to a plain nail and therefore gives an improved resistance to movement. These components typically take the form of triangular-shaped units, constructed from materials such including timber and steel. TCP Truss Clips may be used for general purposes, to resist uplift wherever one member crosses another. Wickes Mending Plate Zinc Plated 100mm Pack 4. Timber Roof Trusses are the most cost-effective way to build a roof – a flexible, practical, easy-to-erect engineered solution which saves time on-site and can use up to 40% less timber than traditional options. Other LUMBERLOK Products. It is likely the nails will be used. It is also the best way to ensure the structural integrity of a building is not being compromised by From foundation to ridge, our connectors will ensure your structure is optimized to be safe and code compliant. TCW & TCP. Global Truss 20" X 20" Aluminum Base Plate For F14 (3. Jan 28, 2021 · E2/AS1 also has information on fixings and layout for some roof materials. Installing roof trusses or joists as part of your building project shouldn’t be too stressful. This is why regular truss maintenance and repair is pertinent to the health of your roof. 8 Steel plates. 1 MB pdf. Many buildings with this type of roof support are still in service today; given their age and inherent The Trussed Rafter Association publishes a wide range of roof construction technical advice and product information on trussed rafters and metal web joists. r Timber Roof TrussesAugust 2020 This document is intended to be used by engineers to provide guidance in designing and eva. A selection of structural fixings from truss clips, timber connectors and nail plates to drywall brackets, helical bar and fixing bands. nailon plate (both sides) 0 mm – nail to lower truss with 90 × 3. He says plywood gussets can be more time-consuming and not much more effective than double scabs. Screws in the FastFix range have core elements to their DNA: Speed of install is a given with smart screw tips giving a rapid start and reduced splitting, and a coarse thread significantly decreases driving. Fasteners. MII-REP06 Standard repair detail for removing a section of the end panel of a floor truss. Wrap over joist hangers, such as be joined on site if they are:overheight (>3. Specifically designed to allow valley trusses to be connected to common trusses in less time, with reduced material wastage the VTCR valley truss clip completely eliminates the need to prepare connecting timbers with time-consuming splay cuts. TRA Ireland Meeting. ervice moisture cycling. An Oak Truss is an intricately crafted structure composed of connected members forming triangular configurations, featuring diagonal rafters, tie beams, king posts, and struts, offering sturdy support for roofing. 2 The i n terface SKU: 38TC. SEE ALL OUR ACCREDITATIONS AND AWARDS. Refer to Section 5 for details. Formed in 1977, BPC Building Products is part of the Vista Group, the UK’s largest independent manufacturer of galvanised and stainless steel building components, offering a quality product range at competitive prices together with service levels that are Get in touch. Roof pitch > 15° - one fixed across the main trussed rafters. AB40 Heavy Duty Angle Brackets. a maximum truss span of 12 m. Helifix Crack Repair HeliBar Stainless Steel Grade 304 1000mm x 6mm 10 Pack(84070) (11) compare. They can assess the extent of the damage, determine the best repair method Where to buy truss fixings. Includes both truss fixing and bottom plate fixing. As with rafter installation, use an 8d nail, making sure that about 2/3 of the nail length ends up in the wall plate. PDF Product Table. All Connectors LUMBERLOK TIMBER CONNECTORS BOWMAC STRUCTURAL BRACKETS BOWMAC STRUCTURAL FASTENERS MITEK FABRICATED PRODUCTS GIB PRODUCTS. Structural Wood Screws. Rafter to Beam Fixings 3 MB pdf. Fold the tabs in the top and bottom chords and attach the nominated wall tiedown brackets using the pre-punched holes in the bottom chord as a reference (if used). The package will be issued with a paper trail which leads directly back to MiTek. The selection of the fixing depends on the magnitude of the support reaction (uplift) and the nature of the support. Speed prong provides temporary attachment for ease of installation. Used to fix trusses, girders and rafters to the wall plate. Truss uplift occurs when a truss's top chords expand because of aring whenever possible. Accommodates Normal Building Movement. What distinguishes Timber Solution’s Oak Trusses is the hidden stainless steel fixings, showcasing both artistry and durability Trusses are always built with an upward camber so that once loaded they deflect about 6mm over time to become straight. 50. Some of this information is available free of charge to all specifiers, designers, contractors, builders, manufacturers and other construction industry professionals; some is restricted to 24 Egmont Road. Shop Truss Plates and Fixings Online or Locate Your Nearest Builders Warehouse Store. Nothing beats a simple connection. FastFix TM. Refer below for Product Data and Installation. The solution to an existing condition: The tops of the interior walls should be un-nailed from the trusses. Crendon roof trusses have up to 20m clear span and are manufactured from TR26 graded timber either 35mm or 47mm thick. Always use a washer under any head or nut in contact with the timber or steel. TCO are the UK stockist of the leading manufacturer, Simpson Strong-Tie, we stock the different types of roof connectors such as hip iron, nail plate, mending plate, truss clip and more. bolted fixings to the support structure. Reliable Delivery Easy Returns Many Ways to Pay! Apr 10, 2019 · The I-joists and plated trusses appeared in the late 60’s and early 70’s to challenge widespread methods and standards. 1 m) overlength (>12 m)one of several trusses meeting over an open space. Bracing requirements for structural Jul 30, 2015 · the truss must be specifically designed in accordance with B1/VM1 and manufactured by an accredited fabricator. We operate ISO9001 Quality Management and the humble Timber Connector, where it all started, is now CE marked and certified for Factory Production Control by BM TRADA. a maximum truss spacing of 900 mm for a heavy roof and 1200 mm for a light roof. Wire Dogs are manufactured as left handed, right handed, and staples, from 4. Fasten the top-plate of interior walls to the bottom of roof trusses with slotted anchors (instead of toenailing). Roof pitch ≤15° - one effective 75mm x 3. 18 Truss Plates and Fixings (46 products) Buy online or present your Builders+ virtual card in store for a chance to win a R5,000 Builders voucher every month. The fixings should be four steel screws or four 75mm x 4mm (8 SWG) round nails. For this example, 2/90 × 3. Its thickness should be at least 0. TECO Truss Clips are available in 2 different types: Truss Clip Woody TCW & Truss Clip Pye TCP. Powapost Dual Coated Heavy Duty Angle - 90 x 45 x 40mm. Also available as MTH/CF/620 with faces plates folded inwards for concealed fixings. The center of trusses may move up and down a bit the first couple years after they’re installed. Global Truss 20" X 20" Aluminum Base Plate For F24 (8. Lumberlok. The Guide. For any roof truss repair, it’s essential to consult with a structural engineer or a professional roofing contractor. £69. This could lead to premature corrosion of nails and fixings. Girt Plate. Material - Produced from 0. Tie downs and fixings for trusses. 99Inc Vat. Jan 3, 2001 · Connection of valley trusses to the supporting truss for a low wind area shall be in accordance with the details shown and described. Valley sets fill in roof spaces that structural framing does not. Do not place the glulam in direct contact. It includes a tab to locate the bracket, which also reduces rotation of the supporting member. Phone: 06 755 9191 (Plant) Presco Prenail Ltd. For fixing a standard truss to a girder truss. Speed Prong for Easy Installation. New Plymouth 4312. The package includes a producer statement PS1 covering B1 and B2, a design statement, and five drawings showing layout with truss to truss fixings, top plate fixings, lintel fixings, slab thickening and roof bracing. 75mm to 1. The best place to buy screws online. Their primary purpose is to distribute the weight of the roof evenly across the supporting walls. Hold the new truss rod so the nut on the end, or the thicker part, is closest to the neck. PO Box 3244. Truss Centres 900 max. Once completed, the roof trusses are transported to the construction site and lifted into place using a crane. As the lift occurs it pulls that ceiling drywall up. Truss lifting, or truss uplift, is when wooden trusses shrink, or cures and the bottom-most piece bows upwards and is most noticeable in the middle. pryda. These range from simple fin plates to more complex ‘spider’ type machined or cast components. Filter Our Guides. a maximum snow load of 2 kPa. GABLE ROOFS – start with a gable truss at each end, fixing it to the top plate at the position marked. Just line up the assemblies and fasten them together for a long lasting, structurally tested connection. 7kN Top Plate to Stud 41 Available in Stainless Steel 304-2B. the load on the ends of the trusses to be no more than 16 kN in both directions - up and down. Phone: 06 759 5460. Galvanised straps should be used to fix the wall plate to the masonry; these straps should be at no more than 2 m centres or alternatively, the wall plate can be fixed using bolts at 1. Truss Clips provide an inexpensive and effective method of fixing trussed rafters to wallplates as recommended in BS 5268 : Part 3. MII-REP04 Standard repair detail to modify truss from top chord bearing to bottom chord bearing. With many hard to get and rare products we are keen to assist you with your product requirements. Avoid moisture. Straps should go under rafters and over ceiling joists. ia. Fix with LUMBERLOK Product Nails 30mm x 3. The fixings/connection for roof members are specified in NZS 3604:2011 Tables 10. A safe working platform within the structure is strongly recommended. “The Guide” is intended to be used only for roof trusses supplied by accredited Multinail Truss Fabricators. uating timber roof truss structures. We offer a full range of structurally rated fasteners for wood frame structures. 4. Size 125mm high x 38mm flanges. These steel trusses are made from lightweight high strength steel which provides inner strength to protect and maintain the roof’s structural integrity and quality of construction. Diagonal Cleat N21. Framing anchors, similarly to truss clips, provide a secure fixing. This occurs when one portion of a truss expands more than the rest, forcing the truss to lift upward at its center and cause a separation between the truss and interior wall. The diameter of the washer should be at least three times the bolt’s. Figure C3-01-01-03. The SDWC uplift values listed were analysed and calculated based on the characteristic values MII-GE90-SP 90 (basic) / 115 (ultimate) mph wind speed. It's formed from 1. Available on orders $50 to $3000. For use in heavy duty applications such as multiple truss units, main trimmer joists, purlin to beam connections or similar situations where unusually heavy loads occur. The binder should be nailed to each rafter crossed with two 3. Trusses can be held down by fixing them directly to the wall plate using proprietary truss clips. Trusses should not be This means that every fret sounds, and most of the time you achieve this by pressing down on the first and twelfth fret to see how straight the neck is. Rafters should not be notched to make the straps flush with the rafter. If there is a big gap: tighten the trussrod. 4kN lintel fixing 38 L2 2. 7 kN in tension are required. x 75mm long galvanised wire nails. Deck Joist Fixings 1. At Minera we understand how crucial it is to get everything right – we are here to help by supplying detailed drawings plus we are only a telephone call or email away should you have any queries. au 7 FINGSIX AT SUPPORTS All fixings at supports should be completed as per Pryda Producer Statement report and Floor Truss Layout as supplied by the Pryda May 19, 2021 · Install slotted anchors. 1 to 10. TFEC 4-2020. Place a board against the broken truss’ flat side, being careful to center the break in the patch or to ensure that the same amount of patch is on both sides of the break. We have put together this MTH/620 Multi-Truss Hanger & concealed flange. Lumberlok Truss to Top Plate Fixing Zinc Galvanised. Install truss patch material. FREE Delivery to the UK and Fast Delivery to overall the World. (19) £10. The truss’s shape is designed to distribute the load evenly, reducing stress on individual timber members. The connector specification lists gravity and uplift values. (6) £4. Multigrip. Install the Half Trusses in the corner of the roof. [13] The TCP truss clip attaches girders, trusses and rafters to wall plates to provide wind restraint. At its core, a roof truss is a pre-fabricated, engineered component that constitutes the framework of a roof's structure. From trusses that get dropped or cut/drilled/notched at the jobsite, to homeowners who want to modify their existing trusses to add a skylight or create attic space to fire-damaged trusses, a multitude of scenarios fall under the broad topic of truss repair. $16 24 each. Lintel Uplift Fixings 30kN 50 KB pdf. The top edge of the binder should be splayed to suit the square bottom chord of th. Have your assistant exert upward pressure At least 2 wire-round nails more than 100 mm in length and 4. Download. Delivery. Lintel Uplift Fixings 18N 56 KB pdf. trapment at connections. MII-REP05 Standard repair to remove end vertical (ribbon notch vertical) Download. Melbourne Truss is one of the leading manufacturers of prefabricated timber trusses and frames in Melbourne. This guide is a comprehensive guide to our This is because roof truss clips are limited to being 38 or 50mm. More info. Stainless Steel Diagonal Cleat N21. As an alternative to a continuous binder a 25 x 38 x 300mm batten can be fixed Sep 5, 2023 · This is a delicate process that requires careful measurement and alignment to ensure the truss’s structural integrity. MII-REP19 Standard repair detail to notch 2×6 top chord of gable truss. Lintel Uplift Fixings 22. Suitable for timber to timber, timber to masonry and timber to steel applications. <p>Truss plates are staggered-tooth metal connector plates designed to connect wood truss members together. One product provides for all alternatives with the bending slot enabling easy on-site bending. SMARTRUSS® solution is an advanced framing technology for roof support system. Roof Connectors are suitable for any roof truss or masonry joint. Allow for dimensional changes in the glulam due to potential in. Galvanised Steel. COMMON PRYDA TIE-DOWN CONNECTORS PRYDA TRUSS TIE PRYDA MULTIGRIP Restraint straps should be fixed to solid noggings with a minimum of four fixings of which one should be in the third rafter. It fixes into steel ranging from 0. 15 mm end nails or an alternative fixing that provides 0. PLX20 Uplift Fixings 1. This guide is updated regularly and our digital version will be updated often to ensure content is always current. Ensure scaffolding is in place and signed off. Add to Basket. Do not attempt to design a timber roof truss structure without adult supervision from a qualified professional (prefer. Simpson Strong-Tie connector-plate manufacturing facilities incorporate state Jan 14, 2013 · Gary Weaver, president of Timber Tech Texas, a manufacturer of roof and floor trusses based in Cibolo, Texas, has been crawling around attics doing truss repairs for 38 years. 100. But it wouldn’t be until 1990 that a light, trimmable, and more practical alternative would appear thanks to the invention of the finger jointed open web floor truss. Product Quantity. 0kN lintel fixing 38 L4 14. BPC Fixings – manufacturer of galvanised and stainless steel building components. 66" Light Duty Triangular Truss) $224. Professional Assessment. 66" Light Duty Box Truss) $224. These offer wind restrain and prevent damage to the truss, which could happen due to skew nailing. This heavy-duty timber-to-timber multi-truss hanger is ideal for supporting heavy loads when installing joists. 15 mm. How does this truss calculator work? The calculator has 3 parts: Input section where you need to add all measurements to The GANG-NAIL® Posi-STRUTTM is a V-shaped metal web stamped from 0. Place the bottom of the truss onto the wall plate, aligning the left edge of the truss with the edge marks placed on the wall plate for alignment. Feb 1, 2008 · Truss uplift involves significant differential movement that ultimately causes cracks to open in drywall. TRUSS-Tite™ truss screw is designed for the assembly of truss components through pre-punched holes. ith masonry or concrete. Avoid ecce. The steel truss members are made from ZINCALUME® steel, a 100% recyclable and an Truss Head Screws - Home - Swiftfix. สกรูโครงทรัส TRUSS-Tite™ – Fixing steel roof and floor trusses. We supply 38mm truss clips, 47mm truss clips and 50mm truss clips. Simpson Strong-Tie - Winchester Road, Cardinal Point, Tamworth, Staffordshire, B78 3HG, 01827 255600; Flight Timber Products Ltd - Earls Colne Business Park, Earls Colne, Colchester, Essex, CO6 2NS, 01787 222336; BPC Building Products Ltd - Flanshaw Way, Wakefield, West Yorkshire, WF2 9LP, 01924 364794 Girder Brackets are a compact bracket designed to fix trusses to the bottom chord of girder trusses or to the face of beams. No Additional Stresses Introduced. Drive the nail through at an angle, beginning the nail 5 cm (2 inches) up from the bottom of the truss. Use three nails for 2×4 chords, two on one side and one on the other, and four nails for 2×6 chords, two on each side. ecific engineering design to carry all member forces across the joints. Truss to Top Plate Fixing Zinc Galvanised. Our online shop has a pictorial menu We’re very familiar with the consent process and our experienced team ensure the (PS1) Truss design, Lintel / Beam and Fixing documentation to support your consent is a compliant, cost effective solution from the get go; reducing avoidable delays with RFI’s from Council. Technical Data Sheet. Our team is dedicated to producing high quality certified products that meet our customers’ exact requirements. Truss clips hold truss or rafter to the wall plate. Buy Truss Clips Structural Fixings at Screwfix. Press the rod into the neck channel and slide it so it takes up all the space in the channel. Obround holes for easier nail driving. The wood screws should be used to fasten the patch on one side of the break. Without the internal walls, the calculated deflection would have been as much as 170mm but only whilst the gang nail truss connectors stayed in place. Pryda FastFix™ is the home of an innovative range of screws making traditional, labour intensive connections a thing of the past. Snow Load to 1. 35mm. This truss calculator is intended for individuals who build their own roofs, or professionals (contractors, architects, quantity surveyors, etc) who need to create a visual drawing of the truss they are building or fixing. 9mm thick galvanised steel to BS EN 10346:2009 +G275 as All trusses are to be fixed to the supporting structure with appropriate fixings, typically Pryda Multigrips etc. . Categories. Add to Cart. HIP OR DUTCH GABLE – start with the Dutch girder truss or the truncated girder, placing it on the top plate at the position marked and temporarily Simpson Strong-Tie is driven by a commitment to design and manufacture structural connectors, fasteners and anchors that improve and simplify traditional building methods while developing performance tested and approved solutions for new ones. Top mounted fixing avoids potential obstructions with linings. Nailon Plates. We offer technical advice on trussed rafters covering all areas from design and specification to delivery and installation. Because they are, in some sense, a cosmetic part of the roof system, some truss manufacturers don't bother Truss clips are designed to connect trusses, girders and rafters to wall plates. Specific requirements for truss fixings will be stated on the truss layout plans provided by the truss supplier. Everyone who comes into contact with our products experiences technical support, advice and aftercare The Strong‑Drive ® SDWC Truss Screw provides a truss and rafter-to-top plate connection as well as a method to fasten stud-to-top and bottom plate. Fax: 06 759 5466. Redistributes Tensile Loads along Masonry. 5 MB pdf. Truss/rafter-to-plate and stud-to-plate connectors resist wind and seismic forces including embedded truss anchors, girder tiedowns, hurricane/seismic anchors, and moisture barrier plates. Note. Support structure The steel beams, columns, trusses, etc. 49 Inc Vat. Fixings required from Table 8. We have a massive selection of screws and consumables available to buy for delivery throughout the UK, Europe and the rest of the world. Gable Roofs – start with a gable truss at each end, fixing it to the top plate at the position marked. S. View all news. Product Details. fixing type required (Type A) Step 5 – Read off the fixing that is required at 600 centres maximum. com. MII-SGE1-150-SP Structural gable end detail. 0 kPa 2x WIRE DOGS Top Plate Packer Top Plate 2x CT200’s (Fill nail holes with LUMBERLOK Product Nails 30 x 3. Fixings in walls Wickes Multi Purpose Builders Fixing Band - 20mm x 10m. 9mm thick galvanised steel to BS EN 10346 +G275 as standard or stainless steel to order. 2. 5 mm diameter, and in accordance with I. 3 times the bolt’s diameter. 9mm diameter galvanised wire. 93" Light Duty Decorative Box Truss) $224. FASTFIT MKIII / MKIII CYCLONIC GIRDER BRACKET. 05Ø nail through bottom chord of valley truss into top chord of supporting truss at each intersection of the trusses. Make sure to toenail on both sides of the truss on each end. Fixing BP1 Sheet Brace Strap 6kN 36 BP2 Sheet Brace Strap 12kN 36 BP3 Stud Anchor 6kN 36 BP4 Stud Anchor 12kN 37 BP6 Bottom Plate Anchor 35 Timber Lintel Fixing system L1 1. Figure 1 Location of additional fixings required in frames. Around the 6th/7th fret there should be a small gap. Avoid the use of details which induce tension perpendicular-to-gra. View all FAQs. Since its inception BAT Metalwork has established itself as the leading supplier of carpenters metalwork and general building products with 24kN Uplift Fixing. Ensure hop-ups and scaffolding edge protection LUMBERLOK range of products which are nailed on-site. MII-REP19A Standard repair detail to notch 2×4 top chord of gable truss. Material – Produced from 0. New Plymouth 4341. The 2024 MiTek On-Site Guide features LUMBERLOK Timber Connectors and BOWMAC Structural Brackets products and updated technical information. +44 (0)1273 423983. Nails. Attach hurricane straps to the trusses where they attach to the wall plates. Angles & Angle Brackets. Fitzroy. 5 mm-thick galvanised steel in accordance with the BS EN 10346:2009 standard for strength, corrosion The MiTek Guide is a quick reference handbook. Click & Collect Delivery. 0kN lintel fixing 38 Top Plate to Stud Connection TPO 0. 1. We manufactures glulam beams, LVL timber, posts, wood flooring, timber crib retaining wall systems and The roof can suffer from localised condensation, especially if not adequately ventilated. Hip or Dutch Gable – start with the Dutch girder truss or the truncated girder, placing it on the top plate at the position marked and temporarily Jan 27, 2024 · You could also ask an employee at a repair shop. MII-SHEET 2 Alternate diagonal bracing to the bottom chord. Pryda’s FastFix™ pre-installed 150mm or 200mm screw configuration makes short work of permanently connecting each truss to the wall frame top plate. Simpson Strong-Tie Truss Clips 38mm x 100mm 20 Pack (623TJ) compare. Fit the new truss rod into the channel with the nut facing the neck. If the wood shrinks in service, the bolts should be retightened. The site joining and fixing is carefully d. www. Using the AS1684 to select the appropriate fixings for a trussed roof frame. Truss Clips provide an inexpensive and effective method of fixing trussed rafters to wallplates. Materials: 0. How to achieve stakeholder buy-in for Net Zero initiatives. The roof tiles had to be taken off completely to allow the remedial work Each jack truss is fitted with Pryda’s truncated standard truss stop (TS Stop) for easy and accurate installation of a truncated standard truss. In 2002, Simpson Strong-Tie introduced a metal connector for a valley-to-truss connection called the VTC2. valley trussed rafter (see figure 3). VIEW PRODUCT…. Before you begin: Check and read all assembly drawings and information provided by the truss supplier. Ensure all personal protective equipment (PPE) is worn and correctly fitted. The plates transfer the load between the timber, creating a rigid truss structure to support the roof’s weight. Remove or cut free the nails from inside the attic. stresses in the member. Stainless Steel Girt Plate. Click & Collect. that transfer self weight, wind and other imposed loads to the building structure, or to foundations. If there's no gap: loosen the trussrod. 105-1: 1977 Wire and cut nails for building purposes, staggered and fixed at either side of the truss, should be used to fix each truss to the wall plate such that no damage to the punched metal plate fixings occurs. All site joints are s. Materials: Steel. Give us a call on. So if you are roofing building a drywal or errecting some decking you will find the correct structural fixing for the job here. Global Truss 20" X 20" Aluminum Base Plate For F23 (8. 91mm ASTM A446 Grade A (yield strength 230 MPa, ultimate strength 310 MPa) steel with a Z275 galvanised coating. The teeth of these connector plates are punched in pairs at right angles to securely connect the pieces of rafter trusses or floor trusses at the joint, allowing for the transfer of loads through the structure. 8kN lintel fixing 38 L3 8. 5kN 48 KB pdf. Support for Bricks 67 KB pdf. Uses include fixing multiple truss units, main trimmer joists and purlin-to-beam connections. Buy online & collect in hundreds of stores in as little as 1 minute! Bolts should be tightened so that the members fit closely. Each has a 95mm shank, and a 35mm leg. £8. He also advises that, to ensure that any sag or deflection in the bottom Bowstring trusses were a popular solution for structurally supporting roofs from the 1900s through the 1950s, especially in buildings where large, open spans were desired (manufacturing facilities, garages, warehouses, among others). Apr 16, 2010 · Although one of the strongest roofing methods to date uses trusses, a broken roof truss can cause great damage to a building and could result in a collapsed roof. If dealing with a set of two, three, or 4 trusses, then framing anchors can go either side of the truss at either end of the wall plate. Also available in Stainless Steel 304. The MiTek Guide is a quick reference handbook designed to assist in the determination of the relevant MiTek fasteners and bracing products which comply with Australian Standards AS1684 and AS4440. Then remove all the ceiling screws within 16 inches of the corners at the center partitions and all the wall screws within 8 inches of the ceiling along the wall. Structural Connector Screws. 18. We have gained a loyal customer base of respected merchants and distributors. 6mm thick. Australia A pocket guide to truss installation. 91mm G300 Z275 Steel. Posi-STRUTTM is available in four depths or sizes: PS20, PS25, PS30 and PS40. Can also be used for general applications as a multi-purpose connector to provide restraint whenever two timber members cross. We cater to all kinds of projects be it commercial, residential and even owner-builders. Registration link for TRA Northern meeting now available. Concrete Fixing Cleats. Tie down the Hip Girder truss to the wall frames with a 32 x 1mm strap brace with the nominated fixings. "The Guide" is intended as a guide only to the installation of Timber Roof Trusses and should only be used by properly trained and qualified staff who are MITEK NZ STRUCTURAL FIXINGS ON-SITE GUIDE. Truss lift is mainly an issue with wood frame construction homes where the non-load bearing drywall walls meet the ceiling. 2m centres. Download Product . The fully-threaded shank engages the entire length of the fastener providing a secure connection. Obround Hole to Ease Nailing. Slotted anchors allow the truss to move without pulling up on the top plate of the interior walls. BAT Metalwork Ltd was formed in October 1980 and is the leading Irish manufacturer of construction fixings and distributor of construction products to builder providers and DIY stores across the country. These trusses must be temporarily braced back to the ground or frame at the panel points. 00. Wire Dog/Staples have been proven by test to be the strongest and most economical timber fastener of its type on the New Zealand market. At Speedy Fixings, we also have available wrap over joist hangers, face fix joist hangers and masonry hangers. Manufactured from heavy duty 3mm thick galvanised steel, these 40mm wide brackets and plates provide a strong connection allowing for the use of bolts, nails, screws and coach screws. Finish: Zinc Coated. Bolts. 15mm diameter, or Type 17-14g x 35mm Hex Head Screws. 15) GIRDER TRUSS TO TOP PLATE FIXING All girder trusses up to a span of 9000 and the above load details are to be fixed to the top plate using the CT200 FIXING shown above LOAD DETAILS Truss Span Sep 25, 2022 · Install Truss Plates. ue qk kb zg rw qb en ug fy uw